Annual system maintenance prevents costly breakdowns of your home’s heating and air conditioning systems.

Annual system maintenance on your home heating and AC systemOur (MVP) super-tunes your system and keeps it running at peak efficiency to prevent breakdowns, save money on fuel, keep you safe, and even add years to the life of your equipment.

5 Benefits of our MVP Plan.

  1. MVP Thoroughly Cleans and Tunes Your Entire System. Some companies clean only the burner. But at Heritage we take tune-ups seriously. We clean, inspect, safety-check and super-tune your entire system.
  2. MVP Prevents Costly, Inconvenient Breakdowns. We do a Preventative Inspection of your entire system to spot small problems early before they become big. We’ll even give you a Preventative Report Card, so you know exactly where you stand.
  3. MVP Adds Years to the Life of Your System. Whether your system is old or relatively new, an annual MVP Super Tune-up keeps your equipment running cleaner and better, so it lasts longer. With the average price of a system being around $7,500-$8,000, this is an important benefit!
  4. MVP Keeps Your Home and Family Safe and Comfortable. We do a complete Safety Test of your system, using state-of-the-art carbon monoxide detection equipment. You’ll sleep better knowing this is taken care of.
  5. MVP Protects Your Warranty. In some cases, missing an annual tune-up can void the warranty on your equipment. With MVP, your yearly maintenance is done on time; you can be sure your warranty stays in effect.

Learn What We Do During Our Maintenance Visit

[twocol_one]

SYSTEM CLEANING
  • Flue Pipe
  • Flue Collector Box
  • Baffles
  • Scrub Passages
  • Combustion Chamber
  • Oil Motors as Necessary
  • Pump Strainer
  • Strainer Gasket
  • Oil Filter Cartridge
  • Drawer Assembly
  • Blast Tube
  • Set Electrodes
  • Change Nozzle
  • Clean Retention Head
  • Clean Transformer Bushings/Springs
  • Check Cad Cell Surface
  • Clean Air Inlet
  • Check Oil Pressure
  • Check All Wire Connections
  • General Boiler Cleanup

[/twocol_one] [twocol_one_last]

SAFETY INSPECTION OF THE FOLLOWING
  • Chimney Draft
  • Barometric Damper
  • Burner Gasket
  • Combustion Chamber
  • Cracks in Block/Heat Exchanger
  • Boiler Pressure
  • Oil Line
  • Sludge/Water in Oil Filter Assembly
  • Non-Restrictive Oil Filter Type
  • Flare Fittings Only
  • Electrode Tips/Porcelains
  • Retention Head
  • Nozzle Centered
  • Cad Cell Bracket Alignment
  • Cad Cell Ohms
  • Burner Insertion Depth
  • Check Oil Cut Off
  • High Limit Check
  • Transformer Test
  • Aquastat
  • Automatic Fill
  • Low Water Cut Off
  • Air Elimination
  • Expansion Tank
  • Circulator
  • Circulator Gaskets/Flanges
  • Relief Valve
  • Zone Valves
  • Purge Valves
  • Temp. Gauge
  • Venting
  • System Free of Leaks
  • Thermostat(s)
  • Service Switch
  • Secondary Switch

[/twocol_one_last]

[twocol_one]

SYSTEM CLEANING
  • Flue Pipe
  • Flue Collector Box
  • Baffles
  • Scrub Passages
  • Combustion Chamber
  • Oil Motors as Necessary
  • Pump Strainer
  • Strainer Gasket
  • Oil Filter Cartridge
  • Drawer Assembly
  • Blast tube
  • Set Electrodes
  • Change Nozzle
  • Clean Retention Head
  • Clean Transformer Bushings/Springs
  • Check Cad Cell Surface
  • Clean Air Inlet
  • Check Oil Pressure
  • Check All Wire Connections
  • General Furnace Cleanup
GENERAL INSPECTION OF THE FOLLOWING
  • Air Filter
  • Condensate Pump
  • Condensate Line
  • Condensate Line Termination
  • Humidifier
  • Humidifier Pad
  • UV Light
  • High Efficiency Air Cleaner
  • Multi Zone Control
  • Zone Dampers
  • Static Pressure Bypass

[/twocol_one] [twocol_one_last]

SAFETY INSPECTION OF THE FOLLOWING
  • Chimney Draft
  • Barometric Damper
  • Burner Gasket
  • Combustion Chamber
  • Cracks in Heat Exchanger
  • Oil Line
  • Sludge/Water in Oil Filter Assembly
  • Non-Restrictive Oil Filter Type
  • Flare Fittings Only
  • Electrode Tips/Porcelains
  • Retention Head
  • Nozzle Centered
  • Cad Cell Bracket Alignment
  • Cad Cell Ohms
  • Burner Insertion Depth
  • Check Oil Cut Off
  • High Limit Check
  • Transformer Test
  • Venting
  • Vent Clearances to Combustibles
  • Vent Termination
  • Vent Piping Supports (5 ft min)
  • Thermostat(s)
  • Service Switch
  • Secondary Switch
  • Area Free of Combustibles/Gas/Liquids
  • Camera Inspection of Heat Exchanger

[/twocol_one_last]

[twocol_one]

SYSTEM CLEANING
  • Flue Pipe
  • Flue Collector Box
  • Clean Burner Tubes
  • Clean Flame Rectifier
  • Clean Air Inlet
  • Pressure Switch Tubes
  • Ignition Assembly
  • Oil Motors as Necessary
  • Check all Wire Connections
  • General Boiler Cleanup

[/twocol_one] [twocol_one_last]

SAFETY INSPECTION OF THE FOLLOWING
  • Area Free of Combustibles/Gas/Liquid
  • Vent Piping
  • Vent Clearances to Combustibles
  • Vent Termination
  • Vent Piping Supports (5ft. min)
  • Boiler Pressure
  • Expansion Tank
  • Combustion Area
  • Cracks in Block/Heat Exchanger
  • High Limit Check
  • Check Rollout Switches
  • Aquastat
  • Automatic Fill Valve
  • Low Water Cut Off
  • Air Elimination
  • Circulator
  • Circulator Gaskets/Flanges
  • Relief Valve
  • Zone Valves
  • Purge Valves
  • Temp. Gauge
  • Venting
  • System Free of Leaks
  • Thermostat(s)
  • Service Switch

[/twocol_one_last]

[twocol_one]

SYSTEM CLEANING
  • Clean Combustion Area
  • Pressure switch tubes
  • Flame Sensor
  • Condensate Trap
  • Flue Pipe
  • Check All Wire Connections
  • General Furnace Cleanup
SAFETY INSPECTION OF THE FOLLOWING
  • Area Free of Combustibles/Gas/Liquids
  • Vent Clearances to Combustibles
  • Vent Termination
  • Vent Piping Supports (5 ft min)
  • High Limit
  • Roll Out Switches
  • Service Switch
  • Igniter/Thermocoupler check
  • Camera Inspection of Heat Exchanger

[/twocol_one] [twocol_one_last]

GENERAL INSPECTION OF THE FOLLOWING
  • Air Filter
  • Thermostat(s)
  • Condensate Pump
  • Condensate Line
  • Condensate Line Termination
  • Wet Switch
  • Emergency Pan
  • Pressure Switch
  • Vent piping
  • Humidifier
  • Humidifier Pad
  • UV Light
  • High Efficiency Air Cleaner
  • Multi Zone Control
  • Zone Dampers
  • Static Pressure Bypass

[/twocol_one_last]

[twocol_one]

SYSTEM CLEANING
  • Condenser Coil
  • Condenser Fan
  • Pad
  • Condensate outlet (if service access)
  • Air Filter (standard)
  • Check Capacitor
  • Check Contactor
INSPECTION OF THE FOLLOWING
  • Thermostat
  • Air Filter
  • Evaporator Coil
  • Condensate pump
  • Condensate line
  • Condensate trap
  • Wet Switch
  • Outdoor Capacitor
  • Outdoor Contactor
  • Outdoor Breaker/Disconnect
  • Liquid Tight Whip
  • Condenser Fan
  • Compressor
  • Pipe Insulation
  • Refrigerant Charge
  • Air Flow

[/twocol_one] [twocol_one_last]

CHECK SYSTEM CONDITIONS
  • Suction Pressure
  • Suction Temperature
  • Measured Superheat
  • Required Superheat
  • Liquid Pressure
  • Liquid Temperature
  • Measured Subcool
  • Required Subcool

[/twocol_one_last]

Ask us about enrolling in our Maintenance Value Plan. We can even set it up for low monthly deductions from your credit/ debit card and schedule the annual tune-ups when convenient for you.